Overview

Our locator combines trusted precision with a user-friendly interface for contractors faced with congested underground conditions, unmarked utilities and increasingly-strict regulations. Durable design with antennae mounted in rubber isolators. The most accurate push-button peak depths on the market. Exclusive three-year warranty and weatherproof guarantee. Available probe option for unlocated or abandoned lines.

Specifications
Model
VERIFIER G3 UTILITY LOCATOR
Category Name
Equipment
Year
2023
Sale Type
New
Manufacturer
Vermeer
operational
Range
Real-time depth measurement up to 33 ft (9.9 m)
Weight
Approximately 7.9 lb (3.6 kg), including eight batteries
Interface
6-pin output connector
Dimensions
When using: 10.3 in x 12.4 in x 4.3 in (26.2 cm x 31.5 cm x 11 cm), When in storage: 8.9 in x 12.4 in x 4.3 in (23 cm x 31.5 cm x 11 cm)
Audio Output
Internal speaker with sound-volume-adjusting function
Battery Type
Eight Alkaline LR20 D batteries, Direct mode: 50 hours, Output 4 mAh at 68°F (20°C), Inductive mode: 20 hours, Output 50% at 68°F (20°C)
Battery Life
Full Power (5 W): 10 hours at 68°F (20°C)
Data Logging
Memorized 400 points of data including depth, current measurement, date and time
Output Power
Maximum 5 W, 80 kHz: maximum 1 W
Current Value
Current value showing on the conductor is displayed for line identity in milliamps
Depth Display
High-precision depth measurement; Line: up to 16 ft (5 m), up to 30 ft (10 m), probe: up to 30 ft (10 m)
Passive Power
50 Hz - 60 Hz, 100 Hz - 120 Hz
Passive Radio
9 kHz to 33 kHz (80 bands)
Battery Status
Low battery indication and press-key readout
Depth Accuracy
16.5 ft (5 m), ± 10%
Operating Modes
Direct-connection mode, inductive mode, *External coil mode
Audio Indication
Internal speaker: alarm, beeping sounds
Output Protection
AC 250 V, 512 Hz: Output is cut off automatically
Visual Indication
LCD: bar graph and digital number
Active Frequencies
38 kHz, ±2%; 9.5 kHz, ±2%; 80 kHz, ±2%; 850 Hz, ±2%; 512 Hz, ±2%
Depth Readout Unit
6.5 ft (2.0m), ± 2.5%; 10 ft (3 m), ± 5%
Measuring Function
Output current: up to 300 mA, line voltage: up to 250 V
Output Frequencies
38 kHz, ±.02% (Standard frequency); 9.5 kHz, ±.02%, (Direct connection mode only); 80 kHz, ±.02% (Direct connection mode only); 512 Hz, ±.02% (Direct connection mode only); Dual: 9.5 kHz/38 kHz, ±0.02% (Direct connection mode only)
Power Save Function
Automatic power off after five minutes of inactivity
Operating Temperature
-4°F to 122°F (-20°C to 50°C)